B&K 200.7 S2 Provozní pokyny

Procházejte online nebo si stáhněte Provozní pokyny pro Audio zesilovače B&K 200.7 S2. B&K 200.7 S2 Operating instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
BK MIKRO 7
Control System for Tool, Object
and Free Space Monitoring
Operating Instructions
Issue 2.01 dated 5.2.2007
MSC Tuttlingen GmbH
Rudolf-Diesel-Straße 17
78532 Tuttlingen
Germany
Tel. +49 7461 925-276
Fax +49 7461 925-268
E-Mail sales-tut@msc.de
www.msc
-tuttlingen.de
id4638000 pdfMachine by Broadgun Software - a great PDF writer! - a great PDF creator! - http://www.pdfmachine.com http://www.broadgun.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - BK MIKRO 7

BK MIKRO 7 Control System for Tool, Object and Free Space Monitoring Operating Instructions Issue 2.01 dated 5.2.2007 MSC Tuttlingen GmbH R

Strany 2

System Components OI: BK MIKRO 7 Page 6 of 32 Rev. 2.01 dated 05.02.2007 2.1.3 Connections Power supply "24 VDC" model:  "+"

Strany 3 - General Notice

OI: BK MIKRO 7 System Components Rev. 2.01 dated 05.02.2007 Page 7 of 32 Selection inputs  "S1" terminal "S2" terminal "

Strany 4

System Components OI: BK MIKRO 7 Page 8 of 32 Rev. 2.01 dated 05.02.2007 Relay outputs The terminals have been designed as dry relay contacts. By s

Strany 5 - OI: BK MIKRO 7 Contents

OI: BK MIKRO 7 System Components Rev. 2.01 dated 05.02.2007 Page 9 of 32 2.1.5 Rotary switches The two rotary switches P1 and P2 on the control uni

Strany 6

System Components OI: BK MIKRO 7 Page 10 of 32 Rev. 2.01 dated 05.02.2007 2.1.6 Toggle switches Using the six toggle switches arranged next to each

Strany 7 - 1 Characteristics

OI: BK MIKRO 7 System Components Rev. 2.01 dated 05.02.2007 Page 11 of 32 "Clockwise / Counter-clockwise" switch (CW/CCW) Direction of ro

Strany 8 - 2 System Components

System Components OI: BK MIKRO 7 Page 12 of 32 Rev. 2.01 dated 05.02.2007 2.2 Scanner 2.2.1 Characteristic properties The scanner housing is cyli

Strany 9

OI: BK MIKRO 7 System Components Rev. 2.01 dated 05.02.2007 Page 13 of 32 2.2.2 Technical data Housing Anodized aluminum Protection type IP 67 Wa

Strany 10

System Components OI: BK MIKRO 7 Page 14 of 32 Rev. 2.01 dated 05.02.2007 2.3 Connection cable Control unit and scanner are connected by a 8-wire

Strany 11

OI: BK MIKRO 7 Mode of Operation Rev. 2.01 dated 05.02.2007 Page 15 of 32 3 Mode of Operation BK MIKRO 7 can be operated in different ways:  Sca

Strany 13

Mode of Operation OI: BK MIKRO 7 Page 16 of 32 Rev. 2.01 dated 05.02.2007 3.2 Output of results  Fault message (K.O.) A fault message will be o

Strany 14

OI: BK MIKRO 7 BK MIKRO 7 with scanner TK7A – Scanning in one direction Rev. 2.01 dated 05.02.2007 Page 17 of 32 4 BK MIKRO 7 with scanner TK7A – S

Strany 15 - Desired position

BK MIKRO 7 with scanner TK7A – Scanning in one direction OI: BK MIKRO 7 Page 18 of 32 Rev. 2.01 dated 05.02.2007 4.1 Teach mode = monitoring with l

Strany 16

OI: BK MIKRO 7 BK MIKRO 7 with scanner TK7A – Scanning in one direction Rev. 2.01 dated 05.02.2007 Page 19 of 32 4.2 Switch mode = monitoring with

Strany 17 - Connector

BK MIKRO 7 with scanner TK7A – Scanning in one direction OI: BK MIKRO 7 Page 20 of 32 Rev. 2.01 dated 05.02.2007 4.2.3 Deflection of wand Rotation

Strany 18

OI: BK MIKRO 7 BK MIKRO 7 with scanner TK7RL – Scanning in both directions Rev. 2.01 dated 05.02.2007 Page 21 of 32 5 BK MIKRO 7 with scanner TK7RL

Strany 19 - 3 Mode of Operation

BK MIKRO 7 with scanner TK7RL – Scanning in both directions OI: BK MIKRO 7 Page 22 of 32 Rev. 2.01 dated 05.02.2007 5.1 Teach mode = monitoring wit

Strany 20

OI: BK MIKRO 7 BK MIKRO 7 with scanner TK7RL – Scanning in both directions Rev. 2.01 dated 05.02.2007 Page 23 of 32 5.1.2 "Start", the re

Strany 21

BK MIKRO 7 with scanner TK7RL – Scanning in both directions OI: BK MIKRO 7 Page 24 of 32 Rev. 2.01 dated 05.02.2007 5.2 Switch mode = monitoring wi

Strany 22 - • S1/S2 selection inputs

OI: BK MIKRO 7 BK MIKRO 7 with scanner TK7RL – Scanning in both directions Rev. 2.01 dated 05.02.2007 Page 25 of 32 5.2.2 Control operation "O

Strany 23

OI: BK MIKRO 7 General Notice Rev. 2.01 dated 5.2.2007 - I - General Notice Safety guidelines These operating instructions contain notices which yo

Strany 24

Cycle Times OI: BK MIKRO 7 Page 26 of 32 Rev. 2.01 dated 05.02.2007 6 Cycle Times Scanning times The following cycle times hold for systems with s

Strany 25

OI: BK MIKRO 7 Status Indication Rev. 2.01 dated 05.02.2007 Page 27 of 32 7 Status Indication 7.1 Yellow LED Fast flashing = Self-test After pow

Strany 26

Status Indication OI: BK MIKRO 7 Page 28 of 32 Rev. 2.01 dated 05.02.2007 7.3 Error messages – Flashing red and green LED Check the following sett

Strany 27

OI: BK MIKRO 7 Installation Notes Rev. 2.01 dated 05.02.2007 Page 29 of 32 8 Installation Notes 8.1 Control voltage connection Fig. 8-1: Control

Strany 28

Installation Notes OI: BK MIKRO 7 Page 30 of 32 Rev. 2.01 dated 05.02.2007 8.2 Mounting bracket The delivering program offers a mounting bracket f

Strany 29 - Minimum angle

OI: BK MIKRO 7 Ordering Information Rev. 2.01 dated 05.02.2007 Page 31 of 32 9 Ordering Information Control unit Article no. BK MIKRO 7

Strany 30 - 6 Cycle Times

Ordering Information OI: BK MIKRO 7 Page 32 of 32 Rev. 2.01 dated 05.02.2007

Strany 31 - 7 Status Indication

General Notice OI: BK MIKRO 7 - II - Rev. 2.01 dated 5.2.2007 Qualification of personnel Only qualified personnel may carry out the following activi

Strany 32

OI: BK MIKRO 7 Contents Rev. 2.01 dated 05.02.2007 Page 1 of 32 Contents 1 Characteristics ...

Strany 33 - 8 Installation Notes

Table of Figures OI: BK MIKRO 7 Page 2 of 32 Rev. 2.01 dated 05.02.2007 Table of Figures Fig. 2-1: Control unit – Connections ...

Strany 34 - • Diodes

OI: BK MIKRO 7 Characteristics Rev. 2.01 dated 05.02.2007 Page 3 of 32 1 Characteristics BK MIKRO 7 is a control system suitable for tool as well

Strany 35 - 9 Ordering Information

System Components OI: BK MIKRO 7 Page 4 of 32 Rev. 2.01 dated 05.02.2007 2 System Components 2.1 Control unit 2.1.1 Characteristic properties T

Strany 36

OI: BK MIKRO 7 System Components Rev. 2.01 dated 05.02.2007 Page 5 of 32 2.1.2 Technical data Housing Insulating material housing, protection clas

Komentáře k této Příručce

Žádné komentáře