B&K Reference 7250 Series II Manuál s instrukcemi Strana 39

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 108
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 38
7250 IPR
(Other)
39
Note
::
Characters represented in gray are flashing and can be edited.
Code Display
Action
Choices
o1.
Select configuration
(Press conf.)
Enter passcode “1200”*.
(Select position with arrow key
and edit number with key.
When the display reads “1200”,
press enter to confirm.)
The transmitter is in HOLD mode
(HOLD icon is on).
Select sensor
InPro 7250 / Other
Select with
arrow key
Proceed with enter
After correct input a
welcome text (CONF) is
displayed for approx.
3 sec.
* Factory setting
When “Other” sensor has been
selected:
Select temperature probe
Select with
arrow key
Proceed with enter
Pt1000
(Pt100,
NTC30,
NTC100)
Enter nominal cell factor (CELL).
Select with arrow key
Proceed with enter
Enter nom. transfer ratio (SFC).
Select with arrow key
Proceed with enter
70098_E_CI7100_2XH.QXD 27.07.2005 9:27 Uhr Seite 39
Zobrazit stránku 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 107 108

Komentáře k této Příručce

Žádné komentáře