CT600/602/610 and CT300/310 BKC-DIP Product Specific Appendices
Version 2.00.09
Updated 12/15/06
Page 43 of 48
Appendix O, Macro Parameters
(0,G,M0=10,5;cs16) Example of Get Serial Macro 16 Message
(0,S,M0=1,5=”Hello”;cs16) Example of Set Serial Macro 1 Message
Supported Macro Types
Type Description
0 Serial Macro Type
Serial Macro Parameters
Parameter Description Parameter Formatting
Identifier Max Values Notes
(in hex) (in hex)
00 Serial Macro Trigger ID 80 Note 1
01 Serial Macro Trigger Code FF Note 2
02 Serial Macro Scrollable 1 Note 3
03 Serial Macro Baud Rate 8 Note 4
04 Serial Macro Output Mask 3F Note 5
05 Serial Macro Message 2000 Note 6
06 Serial Macro Message Size MSB 20 Note 7
07 Serial Macro Message Size LSB FF Note 7
08 Serial Macro Free Space MSB 20 Note 8
09 Serial Macro Free Space LSB FF Note 8
General Notes Regarding Serial Macros
All the parameters of a serial macro are stored with that particular macro. If every identifier is not
specified, default settings are used. The following documents the default settings used for the particular
identifiers:
Parameter Description Default Value
(in hex)
00 Serial Macro Trigger ID 0
01 Serial Macro Trigger Code 0
02 Serial Macro Scrollable 0
03 Serial Macro Baud Rate *
*Same as System Parameter AAh, the System RS-232 Baud Rate
04 Serial Macro Output Mask 3F
05 Serial Macro Message “EMPTY”