CHAPTER 14
Specifications
131
Instantaneous Weather Data:
Wind Dir.
Wind Speed
Instantaneous GPS Data:
Latitude
Longitude
MEASURING RANGES
When using Microphone Type 4950
Dynamic Range: From typical noise floor to max.
level for a 1 kHz pure tone signal, A-weighted: 16.4 to
140 dB
Primary Indicator Range: In accordance with
IEC 60651: A-weighted: 23.6 dB to 122.3 dB
Linearity Range: In accordance with IEC 60804:
A-weighted: 21.5dB to 140.8dB
Linear Operating Range: In accordance with
IEC 61672:
• A-weighted 1 kHz: 24.9 dB to 139.8 dB
• C-weighted: 26.2 dB to 139.8 dB
• Z-weighted: 31.6 dB to 139.8 dB
Peak C Range: In accordance with IEC 61672: 1 kHz,
43.0 dB to 142.8 dB
SAMPLING FOR BROADBAND STATISTICS
Statistics can be based on either L
AF
, L
AS
or L
Aeq
:
•Statistics L
AFN1–7
or L
ASN1-7
are based on sampling
L
AF
or L
AS
, resp., every 10 ms into 0.2 dB wide
classes over 130 dB
•Statistics L
AN1–7
are based on sampling L
Aeq
every
second into 0.2 dB wide classes over 130 dB
Full distribution saved with measurement
The Std.Dev. (Standard Deviation) parameter is calcu-
lated from the Statistics
Measurement Display and Control
MEASUREMENT DISPLAYS
Measurement data displayed as numbers of various
sizes and one quasi-analog bar.
Measured data are displayed as dB values, house-
keeping data as numbers in relevant format.
Instantaneous measurement L
XF
is displayed as a
quasi-analog bar
MEASUREMENT CONTROL
Manual: Manually controlled single measurement
Automatic: Pre-set measurement time from 1 s to
24 hr in 1 s steps
Manual Controls: Reset, Start, Pause, Back-erase,
Continue and Store the measurement manually
BACK-ERASE
The last 5 s of data can be erased without resetting the
measurement
PREFERENCES
Date, Time and Number formats can be specified
Measurement Status
ON SCREEN
Information such as overload and running/paused are
displayed on screen as icons
TRAFFIC LIGHTS
Red, yellow and green LEDs show measurement
status and instantaneous overload as follows:
• Yellow LED flash every 5 s = stopped, ready to
measure
• Green LED flashing slowly = awaiting calibration
signal
• Green LED on constantly = measuring
• Yellow LED flashing slowly = paused, measurement
not stored
• Red LED flashing quickly = intermittent overload,
calibration failed
NOTIFICATIONS
Sends an SMS or email daily at a specified time or if
an alarm condition is fulfilled.
Alarm Conditions:
• Disk space below set value
• Internal battery enters set state
• Change in measurement state
• Reboot of instrument
Calibration
Initial calibration is stored for comparison with later
calibrations
ACOUSTIC
Using Sound Calibrator Type 4231 or custom
calibrator. The calibration process automatically
detects the calibration level when Sound Calibrator
Type 4231 is used
ELECTRICAL
Uses internally generated electrical signal combined
with a typed-in value of microphone sensitivity
CALIBRATION HISTORY
Up to 20 of the last calibrations made are listed and
can be viewed on the instrument
Signal Monitoring
The input signal can be monitored using an
earphone/headphones connected to the headphone
socket
HEADPHONE SIGNAL
Input signal can be monitored using this socket with
headphones/earphones
Gain Adjustment: –60 dB to 60 dB