300
Hand-held Analyzer Types 2250 and 2270 User Manual
L
AFTeq
: Taktmaximal Mittelungspegel as defined by DIN 45641. L
AFTeq
has also been
called L
AFTm5
or L
ATm5F
.
L
avUQ
: Average Sound Level with Time Weighting U = F or S and Exchange Rate
Q = 4, 5 or 6. This is a widely used occupational health noise parameter in
the USA, corresponding to the L
Aeq
used otherwise.
L
Cpeak
: Maximum peak sound level during a measurement. ‘C’ denotes that the C
frequency weighting is used. Used for assessing possible damages to human
hearing caused by very high short-duration noise levels.
L
Cpeak,1s
: Maximum peak sound level during the latest second – is available at any
time. ‘C’ denotes that the C frequency weighting is used. Used for monitoring
the peak levels.
L
den
, L
day
, L
evening
,
L
night
, L
n
:
Noise Indicators for describing the annoyance due to exposure to
environmental noise.
L
den
(day-evening-night noise indicator), L
day
(day-noise indicator), L
evening
(evening-noise indicator) and L
night
(night-noise indicator) are defined by the
European Union. They are based on L
Aeq
over different periods: L
day
over
the day period from 7:00 to 19:00, L
evening
over the evening period from
19:00 to 23:00, L
night
over the night period from 23:00 to 7:00 and L
den
over
the whole day with a penalty of 5 dB(A) for the evening period and a penalty
of 10 dB(A) for the night period.
L
dn
(day-night level) is defined by the Environmental Protection Agency (EPA)
in the USA as a descriptor of noise level based on L
Aeq
over the whole day
with a penalty of 10 dB(A) for night time noise (from 22:00 to 7.00).
L
ep,d
: The Daily Noise Exposure Level is the average A-weighted noise exposure
level for a nominal 8-hour working day. L
ep,d
is also known as L
EX,8h
. L
ep,d
is calculated from the measured L
AE
, the setting of Exposure Time and a
Reference time of 8 h. Used for assessing the noise exposed to a worker
during a working day – in accordance with ISO standards.
The European Noise at Work Directive 2003/10/EC defines the following limit
and action values:
Exposure Limit Value: 87 dB
Upper Exposure Action Value: 85 dB
Lower Exposure Action Value: 80 dB.
L
ep,d,v
: The Daily Noise Exposure Level for a user-defined reference period. L
ep,d,v
is calculated from the measured L
AE
and the settings of Exposure Time and
Reference Time. Used, for example, for calculating a Weekly Noise Exposure
Level, by setting the Reference Time to 40 h.